3/2-Way Directional Valve NAMUR Explosion-Proof Stainless Steel | Ex d IIC T5/T6 Gb | 24VDC | Zone 1 and 2

In stock
SKU: VSNEX02022
Regular price $286.00 USD
Extent
Voltage

3/2 NAMUR Ex-Proof Stainless Steel Directional Valve — Ex d IIC T5/T6 Gb, 24VDC, Zone 1 and 2

Cematic's 3/2 NAMUR Ex-Proof stainless steel directional valve is the component that converts the 24VDC electrical signal from the PLC into the pneumatic signal to open or close the actuator, in facilities with the risk of explosive atmospheres.

Unlike conventional solenoid valves that require additional piping, the NAMUR connection allows direct mounting on the pneumatic actuator. This eliminates piping, fittings, and potential leaks between the two components.

Its stainless steel body also offers greater corrosion resistance than the aluminum model, so it is the correct specification in environments with the presence of aggressive chemical agents. The Ex d IIC T5 Gb / Ex d IIC T6 Gb certification — explosion-proof enclosure — covers Group IIC gases, including hydrogen. Available in 1/4" and 1/2" sizes.

NAMUR — why direct mounting on the actuator eliminates piping and fittings between components

The NAMUR standard defines the dimensions of the interface between the solenoid valve and the actuator. Compatibility between components from different manufacturers is therefore guaranteed. The advantages of this connection compared to conventional piping installation are described below, as in plants with many automated valves, these advantages have a direct impact on installation and maintenance costs:

  • No piping between the valve and the actuator — since the air passes directly from the solenoid to the actuator: The NAMUR connection eliminates the piping between the solenoid and the actuator. Consequently, there are no fittings that can loosen, nor piping that can bend or break in vibrating environments. The installation is also more compact and the actuator response is faster.
  • Mounting with two screws — since installation and replacement time is significantly shorter: The NAMUR solenoid valve is fixed to the actuator with two screws. It does not require special tools or pipe adjustment. Therefore, replacing a defective solenoid in the field takes minutes instead of hours.

NAMUR as an industry standard — why it simplifies field maintenance

  • Industry standard — compatible with most pneumatic actuators in the catalog, as the NAMUR standard is widely adopted: The single- and double-acting pneumatic actuators in the Cematic catalog include the NAMUR interface on top. The NAMUR directional valve is also compatible with actuators from other manufacturers that meet the standard NAMUR dimensions.

Ex d IIC T5/T6 Gb — why the explosion-proof enclosure covers Group IIC, unlike other concepts

The Ex d certification is the explosion-proof enclosure concept. The solenoid's metal enclosure is built to withstand an internal explosion and prevent the flame from propagating to the external atmosphere. It is also the most widely used protection concept in industrial solenoids for classified areas.

  • Ex d — explosion-proof enclosure, as it contains any internal arc or ignition without propagating it to the atmosphere: If a spark occurs inside the solenoid enclosure, the metal enclosure withstands the internal explosion and the hot gases cool down as they escape through the flameproof seals before contacting the external atmosphere.

The solenoid can therefore operate in areas with flammable gases without the risk of external ignition.

  • Group IIC — covers hydrogen and acetylene, although they are the highest-risk gases: Group IIC is the most demanding of the ATEX/IECEx gas classification. It covers Group IIA and IIB gases and, additionally, hydrogen and acetylene. Therefore, this valve is the correct specification in refineries with hydrogen processes, electrolysis, and ammonia synthesis where Group IIB positioners would be insufficient.
  • T5/T6 — maximum surface temperature of 100°C (T5) or 85°C (T6), as they are more restrictive than T4: The T5 class guarantees that the external temperature does not exceed 100°C and T6 85°C. Both are more demanding than T4 (135°C). They cover gases with a lower auto-ignition temperature. The selection between T5 and T6 depends on the gas present in the area.

Stainless steel vs. aluminum — since the body material also determines the service life in corrosive environments

  • Stainless steel body — since aluminum is not suitable in all environments with corrosive agents: The stainless steel body resists aggressive chemical agents — weak acids, alkalis, and vapors — that would degrade the aluminum. Likewise, it is the correct specification in facilities where process fluids or cleaning products come into contact with the outside of the valve.

Technical specifications that define the installation limits of the 3/2 NAMUR Ex-Proof directional valve

Parameter Value
Configuration 3/2 — 3 ports, 2 positions, 1 coil (single)
Installation NAMUR 
Connection size 1/4"
Body material Stainless steel
Operating voltage 24VDC
Ex certification Ex d IIC T5 Gb / Ex d IIC T6 Gb
Ex protection type d — explosion-proof enclosure
Gas group IIC — includes hydrogen and acetylene
Temperature class T5 (100°C) and T6 (85°C) — see model marking
Enabled zones Zone 1 and Zone 2 — Group IIA, IIB, and IIC gases and vapors
Operating temperature 5 °C to +60 °C
Operating pressure 0.15 to 0.8 MPa
Flow coefficient Cv 1.11 Cv (1/4") — 3.85 Cv (1/2")
Power consumption ≤ 3.5 W
IP rating IP65
Application environment Indoor / outdoor
Air connection 1/4"
SKU VSNEX02022

Stainless steel NAMUR Ex-Proof valve vs. aluminum — comparison table to select the correct material according to the environment

Criterion Stainless steel NAMUR Ex-Proof ← This product Aluminum NAMUR Ex-Proof (standard model)
Corrosion resistance ✅ Superior — resists weak acids, alkalis, and aggressive vapors Suitable for standard environments although not for aggressive chemical agents
Ex certification ✅ Ex d IIC T5/T6 Gb — covers Group IIC (hydrogen) Verify — may vary depending on the aluminum model
Environments with frequent chemical cleaning ✅ Correct — stainless steel resists cleaning agents ⚠️ Verify aluminum compatibility with cleaning products
Weight Higher — stainless steel is denser than aluminum ✅ Lower — for installations where component weight is relevant
Relative cost Higher — justified in corrosive environments or processes with H₂ ✅ Lower — for standard environments without special corrosion requirements
Hydrogen processes ✅ Yes — Group IIC covers hydrogen Verify the gas group of the aluminum model certification

Main applications of the 3/2 NAMUR Ex-Proof directional valve where Group IIC is a requirement

  • Single-acting pneumatic actuators in Zone 1 and Zone 2 areas with Group IIC gases: The 3/2 NAMUR configuration is the standard for controlling single-acting actuators — the energized coil sends air to the actuator to open it and the spring closes it when de-energized.

In areas with hydrogen or acetylene, the IIC certification is the only admissible marking, as groups IIA and IIB do not cover those gases.

  • Petrochemical plants and refineries with reforming, hydrotreating, or ammonia synthesis processes: In those units, hydrogen is present in concentrations that classify the area as Zone 1 with Group IIC. The stainless steel NAMUR Ex-Proof valve is, therefore, the correct specification for controlling the process valve actuators in those units.

The stainless steel body also resists hydrocarbon vapors and industrial cleaning agents.

Applications in pharmaceuticals, offshore, and modular systems where stainless steel is also a requirement

  • Chemical and pharmaceutical industry with the presence of flammable gases and frequent cleaning requirements: In pharmaceutical and fine chemical plants where equipment is cleaned with alkalis and acids, the stainless steel body is the correct specification. Likewise, the IIC certification covers volatile organic solvents from Group IIC that may be present in those facilities.
  • Offshore platforms and liquefied natural gas plants where the area is Zone 1 with Group IIC gases: In offshore facilities with the presence of natural gas and possible traces of hydrogen, the IIC certification is correct although the main gas is from Group IIB. Therefore, the NAMUR IIC valve covers those facilities with a greater safety margin than the IIB model.
  • Modular automation systems with NAMUR standard where low maintenance is required: In plants where all pneumatic actuators have a NAMUR interface, this valve simplifies the standardization of the control system. The replacement of a defective unit is, consequently, a low-complexity maintenance task that does not require pneumatic piping specialists.

For advice on compatibility with your classified area, contact the Cematic technical team — technical support →

Technical Data Sheet