Double Flanged Butterfly Valve ANSI 150 | Ductile Iron | SS304 Disc | EPDM Seat

In stock
SKU: PMDF110
Regular price $219.00 USD
Extent

ANSI 150 Double Flanged Butterfly Valve — Ductile Iron Body, SS304 Disc, EPDM Seat, API 609

The double flanged butterfly valve is the most robust design with the greatest face-to-face length in the iron butterfly valve family — its own flanges, integrally cast into the body, make it radically different from the wafer butterfly valve (unflanged, between pipe flanges) and the Lug butterfly valve (threaded holes). Having its own flanges, the valve is bolted directly to the pipe flanges with independent bolts on each side — just like any other flanged component (gate, globe, check valves) — without relying on through bolts that pass through both flanges. This construction makes it the standard option for large diameters, where the face-to-face length of the butterfly valve is sufficient so that the pipe flanges do not need to be perfectly aligned, and where the weight of the valve at large diameters requires the structural rigidity of integral flanges. Body in ductile iron, disc in SS304 (CF8), stem in SS420, and EPDM seat replaceable according to API 609.

Double Flange vs. Wafer vs. Lug — the three types of butterfly valves and when to use each

Criterion Double Flange ← This product Lug Type Wafer Type
Pipe connection Own integral flanges — independent bolts on each side Threaded holes — bolts directly to each flange No flanges — between pipe flanges with through bolts
Face-to-face length Longer — integral flanges add length Short — same as wafer ✅ Minimum — the most compact design
Dead-end service ✅ Yes — independent own flanges ✅ Yes — threaded holes ❌ No — requires both flanges
Large diameter application ✅ First choice — structural rigidity of integral flanges Possible up to certain diameters ✅ Possible — but more flexible at large diameters
Pipe alignment ✅ More tolerant — own flanges compensate for misalignment Medium Requires precise alignment of both flanges
Weight Heavier — integral flanges add material Medium ✅ Lighter — no own flanges
Relative cost Higher — more complex design Medium ✅ Lower
Valve replacement ✅ Like any flanged component — without relying on through bolt length ✅ Easy — remove bolts from the downstream side Requires removing all through bolts
Design standard ✅ API 609 API 609 / ISO 5752 ISO 5752 / API 609

Integral flanges — why they matter in large diameters

In small diameters (2" to 6"), the wafer and Lug butterfly valves are perfectly viable — through bolts are short, pipe flanges are perfectly aligned, and the valve weight is manageable. In large diameters (8" and larger), problems arise that the double flange resolves:

  • Structural rigidity: A 16" or 20" wafer butterfly valve has considerable weight — the pipe flanges must support that weight laterally. The integral flanges of the double flange better distribute the mechanical loads of the valve weight and pipe forces over the body.
  • Misalignment tolerance: In large diameters, the perfect alignment of two pipe flanges separated by the face-to-face length of the valve is harder to achieve in the field. The integral flanges of the double flange are machined with greater precision than the assembly of two pipe flanges — reducing the risk of leaks in the joints due to misalignment.
  • Easier installation: The double flange is installed and removed exactly like a gate or globe valve — without the coordination of through bolts required with a wafer butterfly valve in large diameters.

Construction materials

Component Material
Body (with integral flanges) Ductile iron — greater mechanical strength than gray iron
Disc SS304 (CF8) — stainless steel
Stem SS420 — martensitic stainless steel
Seat EPDM — field replaceable
Actuator mounting ISO 5211

Technical specifications

  • Type: Double flanged butterfly valve
  • Design standard: API 609
  • Actuator mounting: ISO 5211
  • Flange holes: ANSI 150
  • Body material: Ductile iron
  • Disc: SS304 (CF8)
  • Stem: SS420
  • Seat: EPDM — field replaceable
  • Nominal pressure: PN16 (230 psi / 16 bar) at ambient temperature
  • Operating temperature: -20 °C to +110 °C

Fluid compatibility

  • ✅ Potable water and municipal water in large diameters
  • ✅ Clean industrial process water
  • ✅ HVAC water — chilled water and hot water up to 110 °C
  • ✅ Chlorinated water up to 5 ppm
  • ✅ Non-corrosive wastewater with fine solids
  • ✅ Compressed air and non-corrosive gases
  • ⚠️ Water with high chloride levels: SS304 disc may suffer pitting — consult the version with an SS316 disc
  • ⚠️ Temperature above 110 °C: EPDM deteriorates — consult the version with a Viton seat
  • ❌ Hydrocarbons: EPDM is not compatible
  • ❌ Aggressive acids and alkalis: ductile iron body does not resist

Automation — ISO 5211 in large diameters

The ISO 5211 mounting allows the double flanged butterfly valve to be automated with pneumatic or electric actuators. In large diameters (8" and larger), the operating torque is significant — Cematic sizes the correct actuator with the verified safety factor for each diameter and process pressure:

  • Single or double-acting pneumatic actuator: First choice for large diameters where response speed and torque are priorities. The NC single-acting ensures closure upon loss of air supply. View butterfly valves with pneumatic actuator →
  • Gearbox with handwheel: For large diameters where frequent manual operation is required and the necessary torque exceeds the capacity of a lever — the gearbox multiplies the operator's force for tight closure.
  • ON/OFF or modulating electric actuator: For installations without a compressed air network or with SCADA integration. View butterfly valves with electric actuator →

Main applications

  • Municipal potable water distribution — large diameters: The most frequent application of the double flanged butterfly valve in Mexico. Municipal potable water distribution networks in diameters from 8" to 24" use double flanged butterfly valves as section isolation valves. Water operating agencies (SACMEX, CONAGUA, SIAPA, regional OOA) specify the double flange for these diameters according to potable water network design standards.
  • Water treatment plants (PTAP and PTAR) — large diameters: Section isolation in raw water, treated water, and effluent lines in treatment plants where the main line diameters exceed 8". The double flange provides the structural rigidity necessary for the largest diameter valves in these facilities.
  • High-flow pumping systems: Isolation valves on the suction and discharge of high-flow pumps in municipal, industrial, and irrigation pumping stations. Ductile iron resists the mechanical vibrations of the pumps and EPDM covers standard pumped water.
  • Industrial HVAC — large buildings and facilities: Chilled water and hot water distribution in large-scale facility HVAC systems — airports, hospitals, shopping centers, and industrial campuses — where the main pipe diameters require the double flanged butterfly valve.
  • Large-scale agricultural irrigation systems: Irrigation canals, irrigation district distribution systems, and pressurized irrigation heads in large-scale agriculture where the main distribution diameters are 8" to 20" or more.
  • General industry — large diameter process lines: Any industrial application with large diameter process lines with fluids compatible with ductile iron and EPDM — cooling water, process water, industrial effluents — where the double flange provides the necessary robustness and ease of installation.

For the wafer version without own flanges and more compact, see iron wafer butterfly valve →
For the Lug version with dead-end service in smaller diameters, see ANSI 150 Lug butterfly valve →

 

Technical Data Sheet